Home    Charging Pile Test Equipment    DC Pile Production Line Safety Test

DC Pile Production Line Safety Test

Functional characteristics:
·There are single gun and dual gun test modes.
·Meet GB/T18487.1, IEC61851, SAE J1772.
·Test items can be combined freely, and test configurations can be saved and called directly.
·Test data can be saved to generate test reports for sale, and production data can be exported, traced and connected to the MES system.
·The pile number can be entered through the scanning gun, and the test data can be automatically correlated according to the pile number.
Contact Us

Product Details

Function ALR-9000S-safety test system
Insulation Resistance Insulation test voltage 500VDC-1000VDC continuously settable, default 500VDC
Test position Optional: input-PE, output-PE, input-output, default: full test
Test time can be set, default 2S
Criterion 10-100MΩ continuous can be set, the default more than 10MΩ
Dielectric Strength Test Voltage Type AC, default AC
Test Voltage 1000-3000VAC, 1400-4200VDC continuously settable
Test time 5.60S can continuously set the default 5S
Criterion 1.10mA continuous can be set, default ≤ 10mA
Grounding Test The input side PE and the output side PE pass current 25A, read the tester resistance,<0.1Ω