Automatic ATE Test System

ALR-9100S automatic ATE test system is a system solution provided by our company for photovoltaic inverters and energy storage converters (PCS), which is mainly used to test whether their functions and performance meet the design and relevant standard requirements.
Contact Us

Product Details

ALR-9100S automatic ATE test system is a system solution provided by our company for photovoltaic inverters and energy storage converters (PCS), which is mainly used to test whether their functions and performance meet the design and relevant standard requirements. The power grid simulation source and the DC simulation source have parallel expansion interfaces, which supports the testing of various power products.

This automatic test station consists of ATE integrated test system, ATE test mechanism platform and product fixture flow line. The ATE line is connected to the end of the inverter assembly line and aging test equiment, integrating into a straight line operation. The carrier is placed on the flow test line, the ATE station completes the voltage resistance test and electrical performance test, and next machine automatically sorts qualified and defective products, and then the qualified ones are transferred to manual packaging. The test efficiency and product quality are greatly improved by the fully automatic ATE test optimization solution, saving time and reducing costs for equipment manufacturers and testing organizations.

 

Key Features

1. Fully automatic testing.

2. Automatic positioning and docking.

3. Automatically call test cases without manual intervention.

4. Smaller footprint

 

Technical Specifications

Item

data

Input power

220/380V,Three-phase five-wire

Human computer interaction mode

One click start + host computer software + touch screen

Power measurement channel

PV+BAT+AC grid-connected+load

PV Voltage (V)

0-100V/0-750V/0-1200V/0-1500V/0-2000V

BAT Voltage (V)

0-100V/0-750V/0-1200V/0-1500V/0-2000V

AC Voltage (V)

0-450V/0-900V

Power Analyzer

Voltage: 1500V Accuracy: 0.1% 0.04% 0.03% Current: 50-5000KA

Network communication

RS232/485LANCANWIFIBluetooth

Single station cycle

Pre test 6-8 minutes per unit, post test 10 minutes per unit (depending on customer product and workstation)

Transmission method

Lifting and rotating conveyor

Safety protection

Intelligent monitoring, dual closed-loop linkage alarm and fault reset

Air Pressure

0.40.8MPa

Composition of automation station

Test line, fixture, test platform, flow line, docking tooling

Test station

According to the customer site layout and production requirements

Cycle efficiency

≈96%

Operating temperature

-1040℃